What is the cost of Hioki power Analyser?

11 Apr.,2024

 

Goto to know more.

Email Me When Available

Receive updates on when this product will be available for ordering.

*We don’t share your email. You can unsubscribe at any time.

Specifications Measurement line type: Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel CH4 for voltage/current, (all channels AC/DC measurement) Voltage ranges Voltage measurement: 1000.0 V rms or DC, Transient measurement 2.200 kV peak Current ranges 50.000 mA AC/DC to 5.0000 kA AC/DC (depends on current sensor in use) Power ranges 50.000 W to 6.0000 MW (determined automatically based on current range in use) Basic accuracy Voltage: ±0.2% of nominal voltage, Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy, Active power: DC ±0.5 % rdg. ±0.5 % f.s. + current sensor accuracy, AC ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy Measurement items 1. Transient over voltage : 200 kHz sampling
2. Frequency cycle : Calculated as one cycle
3. Voltage (1/2) RMS, Current (1/2) RMS: one cycle calculation refreshed every half cycle
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current : half-cycle calculation
6. Frequency 200 ms: Calculated as 10 or 12 cycles
7. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period
8. Voltage waveform peak, Current waveform peak
9. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Apparent energy, Reactive energy, Energy cost, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor
10. Voltage crest factor, Current crest factor
11. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0 th to 50 th orders
12. Harmonic voltage-current phase angle: 1 th to 50 th orders
13. Total harmonic distortion factor (voltage/ current)
14. Inter harmonic (voltage/ current): 0.5 th to 49.5 th orders
15. K Factor (multiplication factor)
16. (Available in future firmware update) Instantaneous flicker value: As per IEC61000-4-15
17. (Available in future firmware update) IEC Flicker, Δ V10 Flicker` Record Maximum recording interval: 1 year, Maximum number of recordable events: 9999 × 365 days Interfaces SD/SDHC card, RS-232C, LAN (HTTP server), USB 2.0 Display 6.5-inch TFT color LCD (640 × 480 dots) Power supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery pack Z1003 (Continuous use: 8 hr, Charging time: Max. 5 hr 30 m with AC adapter)

What is the cost of Hioki power Analyser?

Hioki PQ3100-04/6000 KIT Three Phase Power Quality Analyzer - Four 6000 Amp Flex Probe Kit

View Details

If you are looking for more details, kindly visit 3c Geophones.